measuring weighing sytems , loadcell i load cell HT series
HT load cell?s resistance to abaxial loads is perfect. It is ideal for silo and tank applications, which is subject to abaxial lateral loads caused by the wind in outer environment. Since its height is lower than column type load cells, it is preferred in such applications. The type with self-spherical pin for the application in push direction and the type, in which metric screw is attached to it, for the application in pull or both push and pull direction, are available. It is produced in 2, 5, 10, 30 ton capacities. Tank and silo weighing, material test machine, weighing platforms and force measurement are its application areas. <br /><br /> Type HT <br /><br /> Accuracy Class<br /> D<br /> <br /><br /> Capacity (Emax)<br /> 2, 5, 10, 30 T<br /> <br /><br /> Minimum dead load<br /> 0 %R.O<br /> <br /><br /> Rated Output R.O<br /> 2,0 mV/V<br /> <br /><br /> Maximum number of load cell interval n max<br /> 1000<br /> <br /><br /> Vmin<br /> Emax / 4000<br /> <br /><br /> Emax / Vmin<br /> 4000<br /> <br /><br /> Combined error<br /> 0,030 %R.O<br /> <br /><br /> Minimum dead load output return(MDLOR)<br /> <;0,0500 %R.O<br /> <br /><br /> Zero balance<br /> 1 %R.O<br /> <br /><br /> Temperature effect on zero<br /> <; 0,014 %R.O/5C<br /> <br /><br /> Temperature effect on output<br /> <; 0,010 %R.O/5°C<br /> <br /><br /> Compensated temperature range<br /> -10 /+40 °C<br /> <br /><br /> Temperature range, safe<br /> -30 /+70 °C<br /> <br /><br /> Maximum safe central overload<br /> 150 %R.O<br /> <br /><br /> Ultimate central overload<br /> 300 %R.O <br /><br /> Excitation<br /> 5 V<br /> <br /><br /> Input empedance<br /> 760±20 // 380±20 Ω<br /> <br /><br /> Output empedance<br /> 700±3 // 350±3 Ω<br /> <br /><br /> Insulation Resistance<br /> >;1000 MΩ<br /> <br /><br /> Conctruction<br /> nickel plated alloy steel<br /> <br /><br /> Environmental Protection<br /> IP67<br /> <br /><br /> Cable Type<br /> 4x0,22 mm<br /> <br /><br /> Cable Length<br /> 2T, 5T - 3 m // 10T, 30T - 15 m<br /> <br /> <br />HT Series Technical Drawing <br /> <br /> <br />HT Series Load Cell Catalog<br /> <br /> HT load cell?s resistance to abaxial loads is perfect. It is ideal for silo and tank applications, which is subject to abaxial lateral loads caused by the wind in outer environment. Since its height is lower than column type load cells, it is preferred in such applications. The type with self-spherical pin for the application in push direction and the type, in which metric screw is attached to it, for the application in pull or both push and pull direction, are available. It is produced in 2, 5, 10, 30 ton capacities. Tank and silo weighing, material test machine, weighing platforms and force measurement are its application areas. <br /><br /> Type HT <br /><br /> Accuracy Class<br /> D<br /> <br /><br /> Capacity (Emax)<br /> 2, 5, 10, 30 T<br /> <br /><br /> Minimum dead load<br /> 0 %R.O<br /> <br /><br /> Rated Output R.O<br /> 2,0 mV/V<br /> <br /><br /> Maximum number of load cell interval n max<br /> 1000<br /> <br /><br /> Vmin<br /> Emax / 4000<br /> <br /><br /> Emax / Vmin<br /> 4000<br /> <br /><br /> Combined error<br /> 0,030 %R.O<br /> <br /><br /> Minimum dead load output return(MDLOR)<br /> <;0,0500 %R.O<br /> <br /><br /> Zero balance<br /> 1 %R.O<br /> <br /><br /> Temperature effect on zero<br /> <; 0,014 %R.O/5C<br /> <br /><br /> Temperature effect on output<br /> <; 0,010 %R.O/5°C<br /> <br /><br /> Compensated temperature range<br /> -10 /+40 °C<br /> <br /><br /> Temperature range, safe<br /> -30 /+70 °C<br /> <br /><br /> Maximum safe central overload<br /> 150 %R.O<br /> <br /><br /> Ultimate central overload<br /> 300 %R.O <br /><br /> Excitation<br /> 5 V<br /> <br /><br /> Input empedance<br /> 760±20 // 380±20 Ω<br /> <br /><br /> Output empedance<br /> 700±3 // 350±3 Ω<br /> <br /><br /> Insulation Resistance<br /> >;1000 MΩ<br /> <br /><br /> Conctruction<br /> nickel plated alloy steel<br /> <br /><br /> Environmental Protection<br /> IP67<br /> <br /><br /> Cable Type<br /> 4x0,22 mm<br /> <br /><br /> Cable Length<br /> 2T, 5T - 3 m // 10T, 30T - 15 m<br /> <br /> <br />HT Series Technical Drawing <br /> <br /> <br />HT Series Load Cell Catalog
|
|
|
check weigher system
Checkweigher, offers the weight control of packaged products carried on the conveyor belts. After weighing, the packages which have less or more weight are removed from the belt manuallty or by means of air. As the measurement is completed, all results are recorded for reporting. <br /><br />Depending on the application, the system might include one belt or three belts as infeed, weighing and outfeed belt. Checkweigher with three belts are used to separate the products from each other and to organize them at the exit. It is easy to install and use with its user friendly interface and an ideal tool for quality control departments
|
|
|
Indicator ( hgx -1000 MODEL)
With its privileged aluminium frame and included 3 digital inputs / 2 relay outputs feature,ability to communicate with PC and PLC systems HGX-1000 is a high precision digital indicator,which can be utilized in packing,dosing,tank weighing,silo weighing, etc.
|
|
|